{"id":5308,"date":"2023-02-15T09:02:48","date_gmt":"2023-02-15T09:02:48","guid":{"rendered":"https:\/\/www.lasermetusa.com\/?post_type=product&#038;p=5308"},"modified":"2025-07-15T09:39:01","modified_gmt":"2025-07-15T09:39:01","slug":"safety-logic-plus","status":"publish","type":"product","link":"https:\/\/www.lasermet.com\/us\/laser-safety-products\/safety-logic-plus\/","title":{"rendered":"Safety Logic Plus"},"content":{"rendered":"\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-text-color has-background wp-element-button\" href=\"https:\/\/forms.monday.com\/forms\/1075647ec316b1a716dfda5869cbc9e9?r=use1\" style=\"color:#1d1f8c;background-color:#ffcc01\" target=\"_blank\" rel=\"noreferrer noopener\">Download Brochure<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Logic for Interlock Systems<\/h2>\n\n\n\n<p>Lasermet&#8217;s Safety Logic Plus (SLP) is a simple, cost-effective and secure concept in which the logic configuration required for a safety Interlock\u00ae system is hardwired in a single logic enclosure. The system makes use of modules that receives input from all Interlock\u00ae switches.<\/p>\n\n\n\n<p>The SLP System is capable of containing all of the logic functions for the safety Interlock<sup>\u00ae<\/sup>. Complicated permissions can be achieved through logic, only able to arm the laser via the Lasermet Interlock<sup>\u00ae<\/sup>&nbsp;Controller when all of the safe conditions have been met.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image is-resized\">\n<figure class=\"alignright size-thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.lasermet.com\/us\/wp-content\/uploads\/sites\/2\/2023\/02\/safety-logic-plus_complex_150px-150x150.png\" alt=\"\" class=\"wp-image-5222\" style=\"width:213px;height:auto\" srcset=\"https:\/\/www.lasermet.com\/us\/wp-content\/uploads\/sites\/2\/2023\/02\/safety-logic-plus_complex_150px-150x150.png 150w, https:\/\/www.lasermet.com\/us\/wp-content\/uploads\/sites\/2\/2023\/02\/safety-logic-plus_complex_150px-100x100.png 100w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><figcaption class=\"wp-element-caption\">Complex wiring structure without using logic<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image is-resized\">\n<figure class=\"alignleft size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"195\" src=\"https:\/\/www.lasermet.com\/us\/wp-content\/uploads\/sites\/2\/2023\/02\/simplified-logic-diagram_300px.png\" alt=\"\" class=\"wp-image-5227\" style=\"width:329px;height:auto\" \/><figcaption class=\"wp-element-caption\">Simplified logic diagram using <br>Safety Logic Plus<\/figcaption><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The diagram above shows the typical complexity and subsequent simplification of circuitry only in pictorial form. Some of the 32 connections in the complex diagram are wired together so that each diagram has the same number of inputs and outputs.<\/p>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<p>Customers can design and build complex safety Interlock\u00ae systems \u00a0and virtually eliminate obsolescence as the Safety Logic Plus has 30+ years life expectancy. The simplified on-site installation techniques reduce installation time and costs while also simplifying testing and fault finding procedures.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">The Need for Safety Logic Plus<\/h2>\n\n\n\n<p>Standard simple Interlock\u00ae systems consist of a series of door contacts connected in series to form a safety loop. This information is sent back to Lasermet&#8217;s Interlock\u00ae controller.<\/p>\n\n\n\n<p>However, with more powerful lasers and a greater number of them, it is even more critical that laser safety interlocks be installed at a low cost and that their logic be easily understood, maintained, and updated, especially when there are new lasers or changes to the facility.<\/p>\n\n\n\n<p>To meet this need, Lasermet developed the Safety Logic Plus concept, which is a non-processor-based fail-safe logic system that integrates all of the logical functions of the Interlock\u00ae system into a single enclosure. All that is required is to connect each door contact and other control to Safety Logic Plus via individual cables. The system&#8217;s logic function is carried out by interconnecting the internal logic modules in accordance with the logic diagram. A competent electrician can wire this.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Installation, maintenance and testing is straightforward<\/li>\n\n\n\n<li>No specialist PLC training is required<\/li>\n\n\n\n<li>The design enables easy and fast fault finding<\/li>\n\n\n\n<li>Logic changes are done within the enclosure<\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<h6 class=\"wp-block-heading has-text-align-center\">INCREASED COMPLEXITY<\/h6>\n\n\n<style>.kt-svg-icons5308_28b114-2b .kt-svg-item-0 .kb-svg-icon-wrap{color:var(--global-palette4, #2D3748);font-size:50px;}.wp-block-kadence-icon.kt-svg-icons5308_28b114-2b{justify-content:center;}<\/style>\n<div class=\"wp-block-kadence-icon kt-svg-icons kt-svg-icons5308_28b114-2b alignnone\"><style>.kt-svg-item-5308_ad0753-c7 .kb-svg-icon-wrap, .kt-svg-style-stacked.kt-svg-item-5308_ad0753-c7 .kb-svg-icon-wrap{font-size:50px;}<\/style>\n<div class=\"wp-block-kadence-single-icon kt-svg-style-default kt-svg-icon-wrap kt-svg-item-5308_ad0753-c7\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_sliders\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"4\" y1=\"21\" x2=\"4\" y2=\"14\"\/><line x1=\"4\" y1=\"10\" x2=\"4\" y2=\"3\"\/><line x1=\"12\" y1=\"21\" x2=\"12\" y2=\"12\"\/><line x1=\"12\" y1=\"8\" x2=\"12\" y2=\"3\"\/><line x1=\"20\" y1=\"21\" x2=\"20\" y2=\"16\"\/><line x1=\"20\" y1=\"12\" x2=\"20\" y2=\"3\"\/><line x1=\"1\" y1=\"14\" x2=\"7\" y2=\"14\"\/><line x1=\"9\" y1=\"8\" x2=\"15\" y2=\"8\"\/><line x1=\"17\" y1=\"16\" x2=\"23\" y2=\"16\"\/><\/svg><\/span><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-theme-palette-7-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:66.66%\">\n<p>Modern Interlock\u00ae systems have a tendency to be configurable in order to provide multiple modes of operation and varying coverage areas. Implementing such systems with point-to-point wiring between the various door contacts and controls within a building presents significant challenges for installation, testing, and fault-finding, raising installation and maintenance costs.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<h6 class=\"wp-block-heading has-text-align-center\">SIMPLICITY AND SAFETY THROUGH HARD-WIRED LOGIC<\/h6>\n\n\n<style>.kt-svg-icons5308_ba8d23-97 .kt-svg-item-0 .kb-svg-icon-wrap{color:var(--global-palette4, #2D3748);font-size:50px;}.wp-block-kadence-icon.kt-svg-icons5308_ba8d23-97{justify-content:center;}<\/style>\n<div class=\"wp-block-kadence-icon kt-svg-icons kt-svg-icons5308_ba8d23-97 alignnone\"><style>.kt-svg-item-5308_ebc13f-8a .kb-svg-icon-wrap, .kt-svg-style-stacked.kt-svg-item-5308_ebc13f-8a .kb-svg-icon-wrap{font-size:50px;}<\/style>\n<div class=\"wp-block-kadence-single-icon kt-svg-style-default kt-svg-icon-wrap kt-svg-item-5308_ebc13f-8a\"><span class=\"kb-svg-icon-wrap kb-svg-icon-ic_locked\"><svg viewBox=\"0 0 8 8\"  fill=\"currentColor\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><path d=\"M3 0c-1.1 0-2 .9-2 2v1h-1v4h6v-4h-1v-1c0-1.1-.9-2-2-2zm0 1c.56 0 1 .44 1 1v1h-2v-1c0-.56.44-1 1-1z\" transform=\"translate(1)\"\/><\/svg><\/span><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-theme-palette-7-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);flex-basis:66.66%\">\n<p>The wiring system can be simplified by using AND and OR gate modules to implement the basic logic. The components are all basic electrical components like hard wired jumper type connectors, relays, and LEDs.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<h6 class=\"wp-block-heading has-text-align-center\">SAFETY THROUGH DESIGN<\/h6>\n\n\n<style>.kt-svg-icons5308_ecfec1-b3 .kt-svg-item-0 .kb-svg-icon-wrap{color:var(--global-palette4, #2D3748);font-size:50px;}.wp-block-kadence-icon.kt-svg-icons5308_ecfec1-b3{justify-content:center;}<\/style>\n<div class=\"wp-block-kadence-icon kt-svg-icons kt-svg-icons5308_ecfec1-b3 alignnone\"><style>.kt-svg-item-5308_51fcb2-94 .kb-svg-icon-wrap, .kt-svg-style-stacked.kt-svg-item-5308_51fcb2-94 .kb-svg-icon-wrap{font-size:50px;}<\/style>\n<div class=\"wp-block-kadence-single-icon kt-svg-style-default kt-svg-icon-wrap kt-svg-item-5308_51fcb2-94\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_checkSquare\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><polyline points=\"9 11 12 14 22 4\"\/><path d=\"M21 12v7a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2V5a2 2 0 0 1 2-2h11\"\/><\/svg><\/span><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-theme-palette-7-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:66.66%\">\n<p>To provide the logic function, the relay-based logic gates are connected using jumper leads. Because each module has its own LED, it is simple to inspect. Every module has a cross checking function applied to it, so that if it fails or there is no input to it, the laser will not arm. Throughout the system, double safety circuits are used.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>It is a fail-safe system<\/li>\n\n\n\n<li>It uses dual channels<\/li>\n\n\n\n<li>It has full cross checking of all circuits<\/li>\n\n\n\n<li>The laser will not arm until all circuits are checked on both channels and all conditions are satisfied including self-checking.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<h6 class=\"wp-block-heading has-text-align-center\">ELIMINATE OBSOLESCENCE<\/h6>\n\n\n<style>.kt-svg-icons5308_23d755-a8 .kt-svg-item-0 .kb-svg-icon-wrap{color:var(--global-palette4, #2D3748);font-size:50px;}.wp-block-kadence-icon.kt-svg-icons5308_23d755-a8{justify-content:center;}<\/style>\n<div class=\"wp-block-kadence-icon kt-svg-icons kt-svg-icons5308_23d755-a8 alignnone\"><style>.kt-svg-item-5308_313e50-b0 .kb-svg-icon-wrap, .kt-svg-style-stacked.kt-svg-item-5308_313e50-b0 .kb-svg-icon-wrap{font-size:50px;}<\/style>\n<div class=\"wp-block-kadence-single-icon kt-svg-style-default kt-svg-icon-wrap kt-svg-item-5308_313e50-b0\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fas_calendar-times\"><svg viewBox=\"0 0 448 512\"  fill=\"currentColor\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><path d=\"M436 160H12c-6.6 0-12-5.4-12-12v-36c0-26.5 21.5-48 48-48h48V12c0-6.6 5.4-12 12-12h40c6.6 0 12 5.4 12 12v52h128V12c0-6.6 5.4-12 12-12h40c6.6 0 12 5.4 12 12v52h48c26.5 0 48 21.5 48 48v36c0 6.6-5.4 12-12 12zM12 192h424c6.6 0 12 5.4 12 12v260c0 26.5-21.5 48-48 48H48c-26.5 0-48-21.5-48-48V204c0-6.6 5.4-12 12-12zm257.3 160l48.1-48.1c4.7-4.7 4.7-12.3 0-17l-28.3-28.3c-4.7-4.7-12.3-4.7-17 0L224 306.7l-48.1-48.1c-4.7-4.7-12.3-4.7-17 0l-28.3 28.3c-4.7 4.7-4.7 12.3 0 17l48.1 48.1-48.1 48.1c-4.7 4.7-4.7 12.3 0 17l28.3 28.3c4.7 4.7 12.3 4.7 17 0l48.1-48.1 48.1 48.1c4.7 4.7 12.3 4.7 17 0l28.3-28.3c4.7-4.7 4.7-12.3 0-17L269.3 352z\"\/><\/svg><\/span><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-theme-palette-7-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:66.66%\">\n<p>This logic system eliminates the obsolescence issues that have already emerged with PLC-based systems, which rely on interface standards and operating systems that rapidly become obsolete. It does not require any programming languages, software, or a computer with an operating system, and thus is unlikely to become obsolete.<\/p>\n\n\n\n<p>Through its fail-safe design, Safety Logic Plus eliminates a variety of issues. All wires are fed directly back to the enclosure where the logical functions are determined from all remote door locks or switches.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>No software<\/li>\n\n\n\n<li>No Programmable Logic Control<\/li>\n\n\n\n<li>No operating system<\/li>\n\n\n\n<li>No specialist training<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<h6 class=\"wp-block-heading has-text-align-center\">SIMPLE CUSTOM DESIGN<\/h6>\n\n\n<style>.kt-svg-icons5308_7bdb88-be .kt-svg-item-0 .kb-svg-icon-wrap{color:var(--global-palette4, #2D3748);font-size:50px;}.wp-block-kadence-icon.kt-svg-icons5308_7bdb88-be{justify-content:center;}<\/style>\n<div class=\"wp-block-kadence-icon kt-svg-icons kt-svg-icons5308_7bdb88-be alignnone\"><style>.kt-svg-item-5308_79442e-99 .kb-svg-icon-wrap, .kt-svg-style-stacked.kt-svg-item-5308_79442e-99 .kb-svg-icon-wrap{font-size:50px;}<\/style>\n<div class=\"wp-block-kadence-single-icon kt-svg-style-default kt-svg-icon-wrap kt-svg-item-5308_79442e-99\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_settings\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><circle cx=\"12\" cy=\"12\" r=\"3\"\/><path d=\"M19.4 15a1.65 1.65 0 0 0 .33 1.82l.06.06a2 2 0 0 1 0 2.83 2 2 0 0 1-2.83 0l-.06-.06a1.65 1.65 0 0 0-1.82-.33 1.65 1.65 0 0 0-1 1.51V21a2 2 0 0 1-2 2 2 2 0 0 1-2-2v-.09A1.65 1.65 0 0 0 9 19.4a1.65 1.65 0 0 0-1.82.33l-.06.06a2 2 0 0 1-2.83 0 2 2 0 0 1 0-2.83l.06-.06a1.65 1.65 0 0 0 .33-1.82 1.65 1.65 0 0 0-1.51-1H3a2 2 0 0 1-2-2 2 2 0 0 1 2-2h.09A1.65 1.65 0 0 0 4.6 9a1.65 1.65 0 0 0-.33-1.82l-.06-.06a2 2 0 0 1 0-2.83 2 2 0 0 1 2.83 0l.06.06a1.65 1.65 0 0 0 1.82.33H9a1.65 1.65 0 0 0 1-1.51V3a2 2 0 0 1 2-2 2 2 0 0 1 2 2v.09a1.65 1.65 0 0 0 1 1.51 1.65 1.65 0 0 0 1.82-.33l.06-.06a2 2 0 0 1 2.83 0 2 2 0 0 1 0 2.83l-.06.06a1.65 1.65 0 0 0-.33 1.82V9a1.65 1.65 0 0 0 1.51 1H21a2 2 0 0 1 2 2 2 2 0 0 1-2 2h-.09a1.65 1.65 0 0 0-1.51 1z\"\/><\/svg><\/span><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-theme-palette-7-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:66.66%\">\n<p>The design is such that any competent engineer who can follow the wiring diagram is able to check, test, modify or replace any modules or wiring. He does not require any diagnostic software, programming skills, any specific operating systems or other potentially obsolete test equipment. The system can be adapted, upgraded and modified at one point within Safety Logic Plus.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>All safety switches are connected to the enclosure.<\/li>\n\n\n\n<li>The enclosure houses all logic functions.<\/li>\n\n\n\n<li>All logic functions are performed using modules.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">The Lasermet Solution<\/h2>\n\n\n\n<p>Alterations to existing conventional&nbsp;<strong>complex site wiring<\/strong>&nbsp;system installations can be difficult and time consuming and therefore expensive. Safety Logic Plus is a cost effective solution.<\/p>\n\n\n\n<p>Often faults can be identified almost immediately due to the design, making&nbsp;<strong>fault-finding<\/strong>&nbsp;a breeze.<\/p>\n\n\n\n<p><strong>Loss of cable identification<\/strong>&nbsp;can often happen to cables during either installation or during the working life of the system when maintenance or modifications to the building or the wiring itself takes place. Safety Logic Plus simplifies identifying unmarked installed cables.<\/p>\n\n\n\n<p>The SLP System greatly helps with\u00a0<strong>maintenance of systems<\/strong>\u00a0and elimination of bugs associated with any software used especially Programmable Logic Controllers. As there is no software it cannot go obsolete. This includes the software itself, the program type (including language) and the operating system on which it runs. Any maintenance or changes are easily implemented for the anticipated lifetime of the equipment which is expected to exceed 30 years.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-theme-palette-7-background-color has-background is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.lasermet.com\/us\/wp-content\/uploads\/sites\/2\/2023\/02\/CALM-for-SLP-2-1024x576.jpg\" alt=\"\" class=\"wp-image-8676\" style=\"width:514px;height:auto\" srcset=\"https:\/\/www.lasermet.com\/us\/wp-content\/uploads\/sites\/2\/2023\/02\/CALM-for-SLP-2-1024x576.jpg 1024w, https:\/\/www.lasermet.com\/us\/wp-content\/uploads\/sites\/2\/2023\/02\/CALM-for-SLP-2-300x169.jpg 300w, https:\/\/www.lasermet.com\/us\/wp-content\/uploads\/sites\/2\/2023\/02\/CALM-for-SLP-2-768x432.jpg 768w, https:\/\/www.lasermet.com\/us\/wp-content\/uploads\/sites\/2\/2023\/02\/CALM-for-SLP-2-1536x864.jpg 1536w, https:\/\/www.lasermet.com\/us\/wp-content\/uploads\/sites\/2\/2023\/02\/CALM-for-SLP-2-600x338.jpg 600w, https:\/\/www.lasermet.com\/us\/wp-content\/uploads\/sites\/2\/2023\/02\/CALM-for-SLP-2.jpg 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">SLP View on the CALM Monitor<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">CALM for Safety Logic Plus Systems<\/h2>\n\n\n\n<p>With the\u00a0<strong>CALM System<\/strong>, Safety Logic Plus circuits are simplified to achieve complex system functionality while easily displaying system status at a glance.<\/p>\n\n\n\n<p>With the SLP View on the CALM monitor, users can view traceable logic circuits making fault-finding a breeze for large systems. The possibilities are endless.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.lasermet.com\/us\/laser-safety-products-usa\/calm-control-and-laser-monitoring-system\/\" target=\"_blank\" rel=\"noreferrer noopener\">Learn more<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<header class=\"entry-header\">\n<header class=\"entry-header\">\n<p>The simple way to build a complex Safety Interlock\u00ae System without using a Safety PLC.<\/p>\n<p>The Safety Logic Plus uses simple logic to achieve a fully-safe and custom Interlock system for laser safety.<\/p>\n<ul>\n<li>Eliminates the obsolescence associated with Safety PLC systems<\/li>\n<li>Lifetime of 20+ years, fully re-configurable throughout lifespan<\/li>\n<li>Hard wired, dual channel, monitored, relay based logic<\/li>\n<li>Very high safety integrity \u2013 PLe to ISO 13849-1 (equivalent to SIL3)<\/li>\n<li>Cost effective<\/li>\n<li>Fault finding made easy with CALM for SLP<\/li>\n<\/ul>\n<\/header>\n<\/header>\n<div class=\"summary\">\u00a0<\/div>\n","protected":false},"featured_media":6349,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_EventAllDay":false,"_EventTimezone":"","_EventStartDate":"","_EventEndDate":"","_EventStartDateUTC":"","_EventEndDateUTC":"","_EventShowMap":false,"_EventShowMapLink":false,"_EventURL":"","_EventCost":"","_EventCostDescription":"","_EventCurrencySymbol":"","_EventCurrencyCode":"","_EventCurrencyPosition":"","_EventDateTimeSeparator":"","_EventTimeRangeSeparator":"","_EventOrganizerID":[],"_EventVenueID":[],"_OrganizerEmail":"","_OrganizerPhone":"","_OrganizerWebsite":"","_VenueAddress":"","_VenueCity":"","_VenueCountry":"","_VenueProvince":"","_VenueState":"","_VenueZip":"","_VenuePhone":"","_VenueURL":"","_VenueStateProvince":"","_VenueLat":"","_VenueLng":"","_VenueShowMap":false,"_VenueShowMapLink":false,"_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":""},"product_brand":[],"product_cat":[53],"product_tag":[41,43,49,61],"class_list":{"0":"post-5308","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-interlock-systems","7":"product_tag-aerospace","8":"product_tag-automotive","9":"product_tag-industrial","10":"product_tag-research-dev","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"product-type-simple","17":"entry","18":"content-bg","19":"loop-entry"},"acf":[],"taxonomy_info":{"product_cat":[{"value":53,"label":"Interlock Systems"}],"product_tag":[{"value":41,"label":"Aerospace"},{"value":43,"label":"Automotive &amp; EV"},{"value":49,"label":"Industrial"},{"value":61,"label":"Research &amp; Development"}]},"featured_image_src_large":["https:\/\/www.lasermet.com\/us\/wp-content\/uploads\/sites\/2\/2023\/02\/SLP-B.png",500,500,false],"author_info":[],"comment_info":0,"_links":{"self":[{"href":"https:\/\/www.lasermet.com\/us\/wp-json\/wp\/v2\/product\/5308","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lasermet.com\/us\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.lasermet.com\/us\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lasermet.com\/us\/wp-json\/wp\/v2\/comments?post=5308"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lasermet.com\/us\/wp-json\/wp\/v2\/media\/6349"}],"wp:attachment":[{"href":"https:\/\/www.lasermet.com\/us\/wp-json\/wp\/v2\/media?parent=5308"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.lasermet.com\/us\/wp-json\/wp\/v2\/product_brand?post=5308"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.lasermet.com\/us\/wp-json\/wp\/v2\/product_cat?post=5308"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.lasermet.com\/us\/wp-json\/wp\/v2\/product_tag?post=5308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}