The following brochures are available to download (requires Adobe Reader)
(see also laser safety labels and laser interlocks)
Reduce interruptions and downtime in your
laser facility with accurate indication of laser status
All Class 3B and Class 4 lasers require interlocking to comply with standard safety practice. However, while this fulfills the safety requirements it can be annoying and even costly to have your laser shut down when an access door is opened. Such interruptions can be avoided either by using a locking interlock system (see ICS-1 brochure), or by providing accurate information regarding your laser status by the use of illuminated signs, or both.
Signs which are left on continuously even when the laser hazard is not present, quickly become ignored, so it is important to use a system incorporating automatic switching. This can be accomplished either directly from the ICS-1 laser interlock control system or by use of the LCU-1 light control unit. Various options are shown below with standard sign panels, but any message can be displayed as required.
| Type | Size (mm) | Weight | Power rating (230 V) |
Automatic switching from ICS-1 | Automatic switching from LCU-1 |
| One-way sign | 360x150x120 | 2.5 kg | 1 x 8 Watt tube | Yes | Yes |
| Two-way sign | 360x300x120 | 5.2 kg | 3 x 8 Watt tubes (two in red section) |
Usually (depends on configuration) |
Yes |
| Three-way sign | 360x425x120 | 6.7 kg | 4 x 8 Watt tubes (two in red section) |
No | Yes |
One-way sign |
|||
| Situation | Switching | Equipment required | |
| 1. | All situations (recommended setup) |
Sign on when laser enabled by interlock system |
ICS-1 |
| 2. | All situations | Sign on only when interlock system switched on |
ICS-1 |
| 3. | All situations | Sign on only when mains power to laser is switched on |
None |
Two-way sign |
|||
| Situation | Switching | Equipment required | |
| 1. | For lasers drawing power from ICS-1 |
Green section on when ICS-1 on (not reset). Red section on when ICS-1 reset (ie laser enabled) | ICS-1 |
| 2. | For lasers interlocked via interlock connector or shutter |
Green section on when ICS-1 on and laser power supply off. Red section on when ICS-1 on and laser power supply on | ICS-1 Double pole switch for laser power supply |
| 3. | All situations | Green section on when ICS-1 on (not reset). Red section on when ICS-1 reset (ie laser enabled) | ICS-1 LCU-1 |
Alternative two-way sign |
|||
| 1. | All situations | Amber section on when ICS-1 turned on (not reset). Red and Amber sections on when ICS-1 reset (ie laser enabled) | ICS-1 |
Three-way sign |
|||
| 1. | For lasers interlocked via interlock connector or shutter |
Green section on when ICS-1 on. Amber section on when ICS-1 on and laser power supply on. Red section on when ICS-1 reset and laser power supply on. |
ICS-1 LCU-1 Double pole switch for laser power supply |
Customised sign panels are available