The ICS-10 is a development of the market leading ICS-1 laser interlock control system, based upon the same tried and tested safety control system technology and therefore having the same certifications to EN 954-1 and EN 61508. It has all the basic functions of the ICS-1 namely:
In addition it has the following extra functions:
1 Requires ICS-CM software upgrade
2 Requires ICS-10-NC network converter
3 Backlight can be switched off
The ICS-10P is a portable version of the ICS-10F, with plug-in interfaces, carry handle, rubber feet and user interface on one end. This can be used in conjunction with interlocked laser blocking screens such as the Lasermet LBS-HD-8 and LBS-HD-4 to form a temporary interlocked enclosure controlling the laser through the usual interfaces (interlock connector, beam shutter or interlocked mains supply4).
4 Interlocked mains supply is hard wired. Other interfaces are plug-in.
| ICS-10F (Fixed) | ICS-10P (Portable) | ICS-10F with IPS-11 | |
| Interlocked mains supply | 10 A | 10 A | 2 x 32 A |
| Interlocked 12 VDC supply for beam shutters | 1 A | 1 A | 5 A |
| Laser interlock connector operator | 2 off | 2 off | 8 off |
| Warning light output | 230 V, 1 A | 230 V, 1 A | 230 V, 1 A |
| Connections | Hard wired to plug in distribution boxes | Plug in | Hard wired to plug in distribution boxes |
| Supply: | 230 V, 13A | 230 V, 13A | 230 V, 3A plus interlocked mains inputs |
| Size | 300 w x 400 h x 100 deep (mm) | 300 w x 100 h x 320 deep (mm) | 600 w x 400 h x 100 deep (mm) |
| Weight | 5.7kg | 5.1kg | |
| Directives | Conforms to Machinery Directive, Low Voltage Directive, EMC Directive | ||
| Standards | Meets EN 954-1 (Cat 3 safety system), EN 61508 (SIL 4), EN 61010, EN 60947-1 | ||